Power - the Output (Max Low Line)
10 W.
|
Power - the Output (Max on - Line)
40 w
|
Power - the Output (Max, VDC)
50 W
|
|
Protection, the Features
Input Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, Overtemperature
|
The Voltage Input (Min, DC)
40 v
|
Voltage Input (Max, DC)
1200V
|
The Control Scheme
Fluxlink
|
|
|
The Over - Temperature Response
Hysteretic
|
|
Temperature - Operating (Max)
150 ° c.
|
Temperature - Operating (Min)
To 40 ° C
|
|
Auto - Restart & Overvoltage Response
Auto - restart, Latch Off
|
|
|
Voltage and the Output (Max)
24 V
|
Switching Frequency (Max)
95 kHz
|
The Voltage and the Output (Min)
5 V
|
The Switching Frequency (min)
25 kHz
|
|
|
Secondary Response
Auto - restart, Latch Off
|
|
|
|
Power - the Output (Max Low Line)
10 W.
|
Power - the Output (Max on - Line)
40 w
|
Power - the Output (Max, VDC)
70 W.
|
|
Protection, the Features
Input Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, Overtemperature
|
The Voltage Input (Min, DC)
40 v
|
Voltage Input (Max, DC)
1200V
|
The Control Scheme
Fluxlink
|
|
|
The Over - Temperature Response
Hysteretic
|
|
Temperature - Operating (Max)
150 ° c.
|
Temperature - Operating (Min)
To 40 ° C
|
|
Auto - Restart & Overvoltage Response
Auto - restart, Latch Off
|
|
|
Voltage and the Output (Max)
24 V
|
Switching Frequency (Max)
95 kHz
|
The Voltage and the Output (Min)
5 V
|
The Switching Frequency (min)
25 kHz
|
|
|
Secondary Response
Auto - restart, Latch Off
|
|
|
|
Power - the Output (Max Low Line)
10 W.
|
Power - the Output (Max on - Line)
20 w.
|
Power - the Output (Max, VDC)
30 W.
|
|
Protection, the Features
Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
|
The Voltage Input (Min, DC)
30 v
|
Voltage Input (Max, DC)
550 v
|
The Control Scheme
Fluxlink
|
|
|
The Over - Temperature Response
Hysteretic
|
|
Temperature - Operating (Max)
150 ° c.
|
Temperature - Operating (Min)
To 40 ° C
|
|
Auto - Restart & Overvoltage Response
Auto - restart
|
Auto - Restart Threshold
90%
|
Cable Drop Compensation
X
|
|
Switching Frequency (Max)
95 kHz
|
|
The Switching Frequency (min)
25 kHz
|
|
|
Secondary Response
Auto - restart
|
|
|
|
Power - the Output (Max Low Line)
7 W.
|
Power - the Output (Max on - Line)
14 w.
|
Power - the Output (Max, VDC)
22 W.
|
|
Protection, the Features
Input Input Overvoltage, Undervoltage, Open the SR FET Detection, the Output Overload, the Output Overvoltage, Output Short Circuit, the Output Undervoltage, Overtemperature
|
The Voltage Input (Min, DC)
30 v
|
Voltage Input (Max, DC)
950 v
|
The Control Scheme
Fluxlink
|
|
|
The Over - Temperature Response
Hysteretic
|
|
Temperature - Operating (Max)
150 ° c.
|
Temperature - Operating (Min)
To 40 ° C
|
|
Auto - Restart & Overvoltage Response
Auto - restart
|
Auto - Restart Threshold
90%
|
Cable Drop Compensation
X
|
|
Switching Frequency (Max)
95 kHz
|
|
The Switching Frequency (min)
25 kHz
|
|
|
Secondary Response
Auto - restart
|